Type your contacts
We are selling portable mechanical ventilators for respiratory support of patients required in the following cases at both the hospital and home:

  • so as not to bring patients to invasive mechanical ventilation;
  • rehabilitation after pneumonia;
  • pneumonia and exacerbations of asthma;
  • chronic lung diseases;
  • worse breathing after surgery.
BIPAP non-invasive ventilator
The BiPAP non-invasive ventilator is suitable for medical institutions and home for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction, carbon dioxide retention, postoperation respiratory support, other respiratory treatment.
The following recommendations pertain to adult and pediatric patients with ARDS who are treated with non-invasive or high-flow oxygen systems.

High-flow nasal oxygen (HFNO) should be used only in selected patients with hypoxemic respiratory failure.

Non-invasive ventilation (NIV) should be used only in selected patients with hypoxemic respiratory failure.

Patients treated with either HFNO or NIV should be closely monitored for clinical deterioration.
a. Treatment principle:

«ased on symptomatic treatment, actively prevent complications, treat basic diseases, prevent secondary infections, and provide organ function support in a timely manner

b. Respiratory support:

(a) Oxygen therapy: Severe patients should receive nasal cannula or mask to inhale oxygen and evaluate in time whether respiratory distress and / or hypoxemia is relieved.

(b) High-flow nasal cannula oxygen therapy or non -invasive mechanical ventilation: When patients have respiratory distress and / or hypoxemia cannot be relieved after receiving standard oxygen therapy, high -flow can be considered Nasal catheter oxygen therapy or non-invasive ventilation. If the condition does not improve or worsens within a short time (1 to 2 hours ), tracheal intubation and invasive mechanical ventilation should be performed in time.


— Reference Diagnosis and treatment of pneumonitis for a new coronavirus infection
(Trial Version 7)
Treatment of severe and critical cases:

Clinical results
WORKING SCHEME:
Filter needs to pay attention to the problem of increased resistance to water overload. The increased resistance needs to be replaced at any time!
How to avoid nosocomial infections with non-invasive
The main qualitative characteristics of the BIPAP non-invasive ventilator are:
  • 2.8''TFT Screen, show airflow and pressure real-time waveform on screen
  • TVV-APCV mode for critical patients who has rapid and shallow breathing (high frequency breathing) and low tidal volume. It mainly aims to get the targeted tidal volume, commonly used for hospital
    ▪ EPR(expiratory pressure relief), Auto-Leak Compensation. Auto-Altitude compensation, Independent airflow channel
  • Inspirate Triggle/Expirate Level/Inspirate Sensitivity: 1-5 level adjustable
  • Parameters lock: all the parameters cannot be changed after setting and self-lock function, keep safety anytime
  • Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects
  • Advanced power management control technology. Self-check before running, eliminate system mistake
  • With lots of alarming, reminding and protection functions
  • Stable and low noise, create quiet work environment for doctors
  • Including humidifier, water tank, power lead, travel bag, user manual, air filter, SD Card, full face mask, air tubing
Ventilation modes:
Sound:
Pressure range:
IPAP:
EPAP:
Data Storage:
Power supply:
DC voltage:
Over-Temperature Protection:
Lock Function:
Screen Auto Sleep:
Backup Rate:
I / E:
Ramp time:
Auto ON/OFF:
Inspirate Sensitivity:
Inspirate Triggle:
Auto Attitude:
Leak Compensation:
Awake Detection:
Breath Event Detection:
Water Capacity:
Humidifier Level:
Expirate Level:
CPAP, Auto, S, T, ST, APCV
<28 Db
2.8-inch TFT, 320x240
4 cm H2O-30 cm H2O
4 cm H2O-30 cm H2O
SD Card
Input 100-240V, 50-60Hz, Output + 24V, 2.5A
2.5 V DC, 2.5 A
Stop automatically, alarm with 4 time
Yes
Auto sleep in 15 minutes
5-50 / min, adjustable
10-80%
0-60 min, regulation 1 min / step
Yes
1-5
1-5
1-5 level
Yes
Yes
Yes
Yes
220 ml
Integrated Heated, 0-5 level
4 cm H2O-30 cm H2O
220ML max
ERP:
Yes, 0-3 level
Alert:
Power off, mask off
Specification:
Screen:
  • Machine: L28 * W14 * H 9.5cm
  • Net weight: 1.6 KG
  • 1 unit/Carton: L38 * W35 * H 16cm
  • Gross weight: 3.9 KG
  • Volume weight: 4.5 KG
Size:
    Certificates:
    Our partners' products are officially recognized at the international level, which is confirmed by the required certification. Ventilators have undergone all needed testing and we have all test reports required. At the production stage, ventilator pass a thorough quality control check at every stage.
    Contact our support and sales team
    Our team is happy to answer your sales questions. Fill out the form and we will be in touch as soon as possible.
    By filling out the form and clicking on the button, you agree to privacy policy and the collection and processing of personal data.
    Estonia
    11415, Tallin, 47 Peterburi Tee street
    Tel: +37281707633
    Email: sales@aiiahealthcare.com
    © 2020 aiia Healthcare
    Healthcare
    Medical solutions
    Ukraine
    01003, Kyiv, 37 Mendeleev street